Communication Driver

DE688 Forced Air Cooling Series

Supports resolver encoders.

Supports EtherNET, CAN_BUS and SABUS communication.

Suitable for application scenarios that use hydraulic oil as the working medium, it supports both pressure closed-loop mode and speed mode.


- DE688 -

- DE688 -

- DE688 -

Advantage

    • Enhanced Performance, Precise Control, Simplified Operation Include an operation panel to facilitate commissioning.
      With a high-speed DSP , achieving increased processing speed and storage capacity.
      Quick switch between linkage and follow-up control modes; diverse control modes to accommodate various application requirements.
      AUSTONE control platform, bringing better control algorithm and accuracy.
      Allow digital communication via NET, CAN, SA-BUS, and other protocols with the master computer; this enables more visual data monitoring and modification.

    • Multiple Protection Disconnected network alarm.
      Comprehensive protection and monitoring, including a variety of safeguard functions including short circuit, overcurrent, overvoltage, undervoltage, and etc.
      Add the function to set the speed-rising edge delay.
      Dust prevention, an independent air duct, and rapid fan replacement without disassembly.

    • Standard EMC Design, Certified by CE


Parameters

Model

Input Voltage/V

Output Power/ kW

Rated Current/A

DE688K1F3_XXXX

AC 3PH

380~480V

(-15%~10%)

11

25

DE688K5F3_XXXX

15

32

DE688K8F3_XXXX

18.5

37

DE688J2F3_XXXX

22

45

DE688I0F3_XXXX

30

60

DE688I7F3_XXXX

37

75

DE688H5F3_XXXX

45

91

DE688G5F3_XXXX

55

112

DE688E5F3_XXXX

75

150

DE688C0F3_XXXX

90

176

DE688A1F3_XXXX

110

210

DE688A3F3_XXXX

132

253

DE688A6F3_XXXX

160

304


Technical Parameters

Input Power

Input Voltage(V)

AC 3PH 380~480V(Fluctuation range -15%~10%, AC 323~528V, 380V drive)

Fluctuation range -10%~20%, AC 198~264V, 220V drive

Input frequency(Hz)

50Hz/60Hz

Output Power

Output Voltage(V)

0~480V

Output Power(kW)

Please refer to the rated values

Output Current(A)

Control Performance

Control Method

Closed-loop vector control

Type of Motor

AC permanent-magnet synchronous motor

Control Mode

Pressure closed-loop mode, speed mode

Maximum Output Frequency

300Hz

Instruction Setting

CHAB:Analog quantity, internally specified, EtherNET, CAN_BUS

THBB:SABUS

Overcurrent Capacity

Maximum 2 times

Overload Capability

At 4kHz carrier wave: 120% rated current for 30 minutes. 150% rated current for 90 seconds, 180% rated current for 8 seconds, 200% rated current for 1 second

Peripheral Interface

Analog Input

CHAB:3 channels,DC0~10V

THBB:1 channels,DC0~10V

Analog Output

CHAB:2 channels,DC0~10V

Digital Switch Input

CHAB:6 channels

THBB:2 channels

Digital Switch Output

4 channels

Encoder Interface

Resolver

Communication Interface

CHAB:EtherNET;CAN_BUS

THBB:EtherNET;SABUS

Protective Function

Protective functions: overcurrent, overvoltage, undervoltage, phase loss, over temperature, overload and short circuit protection

Others

Installation

Support wall mount

Operating Ambient Temperature

’-10℃~50℃(Derate when the temperature rises beyond 40°C)

Protection Class

IP20

Type of Cooling

Forced air cooling

Braking Unit

90kW and below: built-in; above 90kW: external.

Brake Resistor

Optional, externally installed

Reactor

30~55kW built-in DC reactor, Other alternatives: externally installed


    Return