Hot Runner Controller

M20-M2
Integrated Hot Runner Controller

A hot runner controller is a device that regulates the interior temperature of a system. It is generally used for mold thermal control on injection molding machines.

Application advantages

  • Save raw materials, cut expenses, and enhance automation
  • Simple process adjustments, shorter molding cycles, and increased efficiency
  • Enhance the appearance, performance, and quality of the product
  • Support multi-cavity molds to boost production while maintaining consistent product quality across all mold cavities
  • Used in the manufacturing of large and unique products
  • Extend the range of applications for injection molding

Advantage

    • PID self-learning temperature control

    • Detection of heater damage

    • Balanced heating across all temperature ranges

    • Function of temperature curve

    • Automatically determines whether the thermocouple and heating output are properly connected

    • Function of dehumidification

    • Extensive alarm capabilities

Parameters

Item

Specifications

Input Power

Three-phase five-wire AC380~415V / three-phase four-wire AC200~240V

Control Module

AC85~265V

Supply Frequency

50/60Hz automatic conversion

HMI

12-inch color touch screen

Input Type

J/K thermocoupl

Measurement Accuracy

±0.25%F.S.

Control Accuracy

±0.5℃

Control Mode

Closed loop (AUTO), Open loop (manual)

Temperature Control Range

0~450℃(32~842℉)

Output Mode

Adjust voltage by changing breakover phase angle / Adjust power at regular time

Rated Load

240VAC,15A/Temperature zone

Power Protection

Overvoltage protection module

Input Protection

Diagnosis of inversely connected circuits, open circuits, dislocation and other conditions semiconductor fuses.

Output Protection

Diagnosis of short circuit, overload, dislocation and other conditions; ceramic fuse tubes

Alarm Type

Flashing indicator lights, alarm codes, and warning buzzers

Working Environment

0~50°C(32~122℉), 20~90%RH, no condensation


Function

Alarm function

Protection measures

    Return